{"id":7199,"date":"2023-08-24T10:35:44","date_gmt":"2023-08-24T08:35:44","guid":{"rendered":"https:\/\/limodor.dev-web.at\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/"},"modified":"2023-10-31T19:46:18","modified_gmt":"2023-10-31T18:46:18","slug":"airclean","status":"publish","type":"page","link":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/","title":{"rendered":"AirClean"},"content":{"rendered":"\n\t<section class=\"section section-space\" id=\"section_1847055618\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-1945878309\">\n\n\n\t<div id=\"col-1459859832\" class=\"col medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div class=\"breadcrumbs-row\"><div class=\"breadcrumbs-container\"><div class=\"breadcrumb-element\"><a href=\"https:\/\/www.limodor.com\/en\/vents\/\"><span>Solutions<\/span><\/a><div>><\/div><\/div><div class=\"breadcrumb-element\"><a href=\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/\"><span>Ventilation systems<\/span><\/a><div>><\/div><\/div><div class=\"breadcrumb-element\"><a href=\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/\"><span>Central ventilation system<\/span><\/a><div>><\/div><\/div><div class=\"breadcrumb-element\"><a href=\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/\"><span>AirClean<\/span><\/a><div class=\"ricegrain-container Cherryrot\"><\/div><\/div><\/div><\/div>\n\n<h1>Airclean<\/h1>\n<div class=\"is-divider divider clearfix\" style=\"margin-top:0px;margin-bottom:0px;max-width:40%;background-color:rgb(222, 51, 73);\"><\/div>\n\n\t<div id=\"gap-1457383961\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1457383961 {\n  padding-top: 10px;\n}\n@media (min-width:550px) {\n  #gap-1457383961 {\n    padding-top: 20px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n\n<p>Available in two configurations, the AirClean central ventilation system impresses in the cold season with high heat recovery rates of over 80%. The very low power consumption of the supply and exhaust air units and the option to switch to demand ventilation in summer also saves a lot of energy. This ensures climate protection and living comfort. AirClean 180 (for small and medium-sized apartments) or AirClean 300 (for large apartments and houses) provide a comfortable climate fully automatically through smart, central ventilation control.&nbsp; Allergy protection is supported by filters against dust, pollen and other pollutants in the air intake. Used air, bacteria and viruses, but also humid sauna air or cigarette smoke are quickly extracted with decentralized LIMODOR exhaust air units. Heat recovery takes place via an efficient heat exchanger. Optional integrated silencers ensure whisper-quiet air exchange.<\/p>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-630915159\" class=\"col medium-12 small-12 large-6 medium-col-first\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_165359310\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner image-cover dark\" style=\"padding-top:100%;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2000\" height=\"2000\" src=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung.jpg 2000w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung-300x300.jpg 300w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung-1024x1024.jpg 1024w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung-150x150.jpg 150w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung-768x768.jpg 768w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung-1536x1536.jpg 1536w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung-510x510.jpg 510w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AIrClean_Inhaltsseite_systemdarstellung-100x100.jpg 100w\" sizes=\"auto, (max-width: 2000px) 100vw, 2000px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_165359310 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1847055618 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_1649688921\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\t<div class=\"is-border\"\n\t\tstyle=\"border-color:rgb(0, 105, 180);border-width:3px 0px 3px 0px;\">\n\t<\/div>\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row row-collapse row-full-width align-center\"  id=\"row-82901937\">\n\n\n\t<div id=\"col-1182409308\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner text-center\"  >\n\t\t\t\n\t\t\t\n\n<h3>Advantages<\/h3>\n<div class=\"icon-slider-container\"><div class=\"e5-slider-elements owl-carousel owl-theme\"><div class=\"e5-icon-container\"><div class=\"e5-icon-animation\"><div class=\"lottie-placeholder\" data-src=\"\/wp-content\/uploads\/2023\/08\/Beseitigung-unangenehmer-Gerueche.json\"><\/div><\/div><div class=\"e5-icon-text\"><span>Effective elimination of unpleasant odors<\/span><\/div><\/div><div class=\"e5-icon-container\"><div class=\"e5-icon-animation\"><div class=\"lottie-placeholder\" data-src=\"\/wp-content\/uploads\/2023\/08\/Beseitigung-von-Feuchtigkeit.json\"><\/div><\/div><div class=\"e5-icon-text\"><span>Rapid reduction of humid stuffy air<\/span><\/div><\/div><div class=\"e5-icon-container\"><div class=\"e5-icon-animation\"><div class=\"lottie-placeholder\" data-src=\"\/wp-content\/uploads\/2023\/08\/Energiekostenersparnis.json\"><\/div><\/div><div class=\"e5-icon-text\"><span>Energy cost savings through demand-oriented control technology<\/span><\/div><\/div><div class=\"e5-icon-container\"><div class=\"e5-icon-animation\"><div class=\"lottie-placeholder\" data-src=\"\/wp-content\/uploads\/2023\/08\/Energieeffizient.json\"><\/div><\/div><div class=\"e5-icon-text\"><span>Energy-efficient EC motor technology<\/span><\/div><\/div><div class=\"e5-icon-container\"><div class=\"e5-icon-animation\"><div class=\"lottie-placeholder\" data-src=\"\/wp-content\/uploads\/2023\/08\/Vortemperierte-Frischluft.json\"><\/div><\/div><div class=\"e5-icon-text\"><span>Pretempered fresh air<\/span><\/div><\/div><div class=\"e5-icon-container\"><div class=\"e5-icon-animation\"><div class=\"lottie-placeholder\" data-src=\"\/wp-content\/uploads\/2023\/08\/Steuerungsvarianten.json\"><\/div><\/div><div class=\"e5-icon-text\"><span>Numerous control variants for every need<\/span><\/div><\/div><div class=\"e5-icon-container\"><div class=\"e5-icon-animation\"><div class=\"lottie-placeholder\" data-src=\"\/wp-content\/uploads\/2023\/08\/Kombinierbar.json\"><\/div><\/div><div class=\"e5-icon-text\"><span>Can be controlled individually as individual elements or in combined operation<\/span><\/div><\/div><div class=\"e5-icon-container\"><div class=\"e5-icon-animation\"><div class=\"lottie-placeholder\" data-src=\"\/wp-content\/uploads\/2023\/08\/Schalldaemmung.json\"><\/div><\/div><div class=\"e5-icon-text\"><span>Whisper silent operation<\/span><\/div><\/div><\/div><div class=\"e5-slider-navigation\"><img decoding=\"async\" alt=\"Pfeil links\" class=\"arrow-left\" src=\"https:\/\/www.limodor.com\/wp-content\/mu-plugins\/limodor\/images\/right-arrow.svg\" \/><img decoding=\"async\" alt=\"Pfeil rechts\" class=\"arrow-right\" src=\"https:\/\/www.limodor.com\/wp-content\/mu-plugins\/limodor\/images\/right-arrow.svg\" \/><\/div><\/div>\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1649688921 {\n  padding-top: 40px;\n  padding-bottom: 40px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section section-space\" id=\"section_1314879967\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-154986617\">\n\n\n\t<div id=\"col-89588776\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner text-center\"  >\n\t\t\t\n\t\t\t\n\n<h2>Functions<\/h2>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-49311388\">\n\n\n\t<div id=\"col-498871092\" class=\"col ricegrain sunnyyellow medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t<div class=\"is-border\"\n\t\tstyle=\"border-color:rgb(0, 105, 180);border-width:0px 2px 0px 0px;\">\n\t<\/div>\n\t\t\t\n\n<h4>The exhaust air<\/h4>\n<p>LIMODOR individual ventilation units with a permanent base load stage of 30m\u00b3\/h in winter operation are placed in the sanitary rooms and connected to a common exhaust air duct, just like a conventional single-pipe ventilation system. The only difference is that the exhaust air is not discharged through the roof, but through the heat exchanger box and then through the outside wall into the open air. Each of these ventilation units can be switched individually to the operating ventilation mode (60m\u00b3\/h) by means of an overrun relay, interval relay, humidity control, motion detector or similar. This brings the advantage that the control of each fan can be adapted to the local conditions.<\/p>\n<p>3 LIMODOR air handling units \u00e1 60\/30 m\u00b3\/h, 230 V \u02dc, 11\/7 W, 0,075 A, 32\/26 dB(A)<\/p>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-498871092 > .col-inner {\n  padding: 0px 0px 0px 0px;\n}\n@media (min-width:550px) {\n  #col-498871092 > .col-inner {\n    padding: 0px 50px 0px 0px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-2124110758\" class=\"col ricegrain sunnyyellow medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h4>The supply air<\/h4>\n<p>The supply air is supplied to the bedrooms and living rooms by means of an electronically controlled supply air box via the heat exchanger and LIMODOR supply air valves. The supply air volume is always controlled as a function of the exhaust air volume. This means that the supply air volume automatically adapts to the operating state (basic or full load) of the LIMODOR individual ventilation units and thus ensures that no underpressure or overpressure occurs in the building or in the residential unit.<\/p>\n<p>1 AirClean supply air fan box max. 225 m\u00b3\/h, 230 V \u02dc, max. 32 W, 0.30 A, max 35 dB(A)<\/p>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-2124110758 > .col-inner {\n  padding: 0px 0px 0px 0px;\n}\n@media (min-width:550px) {\n  #col-2124110758 > .col-inner {\n    padding: 0px 0px 0px 20px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row row-full-width align-middle align-center\"  id=\"row-1014440481\">\n\n\n\t<div id=\"col-1650169678\" class=\"col medium-10 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner text-center\"  >\n\t\t\t\n\t\t\t\n\n<h4>The overflow<\/h4>\n<p>The overflow between the individual rooms takes place via the connecting doors (door slot at the bottom) or via specially installed LIMODOR overflow openings. These openings should always be placed so that the air flows through the rooms as evenly as possible and over the entire area. The supply and exhaust air of a room should be diagonal, if possible.<\/p>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1314879967 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_1733624675\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row align-center\"  id=\"row-1776451344\">\n\n\n\t<div id=\"col-2090692351\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner text-center\"  >\n\t\t\t\n\t\t\t\n\n<h2>Product comparison<\/h2>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row row-collapse align-middle\"  id=\"row-1653187534\">\n\n\n\t<div id=\"col-1351337918\" class=\"col medium-7 small-12 large-7\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h4>AirClean 180<\/h4>\n<div class=\"row row-collapse\"  id=\"row-1613459393\">\n\n\n\t<div id=\"col-750810519\" class=\"col ricegrain cherry medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<ul>\n<li>Scope of application: apartment<\/li>\n<li>Volume flow: 60 &#8211; 180 m\u00b3 \/h<\/li>\n<li>Heat recovery rate: &gt;80%<\/li>\n<li>Voltage 230V<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-903393023\" class=\"col ricegrain cherry medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<ul>\n<li>Power consumption: 6-65 watts<\/li>\n<li>Intrinsic noise: exhaust air 32dB(A), supply air 35dB(A)<\/li>\n<li>Filter class: supply air F5, exhaust air G4<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1351337918 > .col-inner {\n  padding: 20px 15px 0px 15px;\n}\n@media (min-width:550px) {\n  #col-1351337918 > .col-inner {\n    padding: 0px 20px 0px 10px;\n  }\n}\n@media (min-width:850px) {\n  #col-1351337918 > .col-inner {\n    padding: 0px 40px 0px 0px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-631220633\" class=\"col medium-5 small-12 large-5 medium-col-first\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover rounded-edges x md-x lg-x y md-y lg-y\" id=\"image_1696358610\">\n\t\t<a class=\"image-lightbox lightbox-gallery\" title=\"\" href=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean180_Aufbauskizze.jpg\">\t\t\t\t\t\t<div class=\"img-inner image-color image-cover dark\" style=\"padding-top:56.25%;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2000\" height=\"1600\" src=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean180_Aufbauskizze.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean180_Aufbauskizze.jpg 2000w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean180_Aufbauskizze-300x240.jpg 300w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean180_Aufbauskizze-1024x819.jpg 1024w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean180_Aufbauskizze-768x614.jpg 768w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean180_Aufbauskizze-1536x1229.jpg 1536w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean180_Aufbauskizze-510x408.jpg 510w\" sizes=\"auto, (max-width: 2000px) 100vw, 2000px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/a>\t\t\n<style>\n#image_1696358610 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\t<div id=\"gap-489525016\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-489525016 {\n  padding-top: 50px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<div class=\"row row-collapse align-middle\"  id=\"row-1433858388\">\n\n\n\t<div id=\"col-24899044\" class=\"col medium-7 small-12 large-7\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h4>AirClean 300<\/h4>\n<div class=\"row row-collapse\"  id=\"row-1820321002\">\n\n\n\t<div id=\"col-1368946722\" class=\"col ricegrain cherry medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<ul>\n<li>Scope of application: apartment, single-family house<\/li>\n<li>Volume flow: 90- 300 m\u00b3 \/h<\/li>\n<li>Heat recovery efficiency: 88 &#8211; 91%.<\/li>\n<li>Voltage 230V<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1461312573\" class=\"col ricegrain cherry medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<ul>\n<li>Power consumption: 30-115 watts<\/li>\n<li>Intrinsic noise: Exhaust air 32dB(A)<\/li>\n<li>Filter class: supply air F7, exhaust air G4<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-24899044 > .col-inner {\n  padding: 20px 15px 0px 15px;\n}\n@media (min-width:550px) {\n  #col-24899044 > .col-inner {\n    padding: 0px 20px 0px 10px;\n  }\n}\n@media (min-width:850px) {\n  #col-24899044 > .col-inner {\n    padding: 0px 40px 0px 0px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-931346547\" class=\"col medium-5 small-12 large-5 medium-col-first\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover rounded-edges x md-x lg-x y md-y lg-y\" id=\"image_1802420748\">\n\t\t<a class=\"image-lightbox lightbox-gallery\" title=\"\" href=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean300_Aufbauskizze.jpg\">\t\t\t\t\t\t<div class=\"img-inner image-color image-cover dark\" style=\"padding-top:56.25%;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"2000\" height=\"1600\" src=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean300_Aufbauskizze.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean300_Aufbauskizze.jpg 2000w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean300_Aufbauskizze-300x240.jpg 300w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean300_Aufbauskizze-1024x819.jpg 1024w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean300_Aufbauskizze-768x614.jpg 768w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean300_Aufbauskizze-1536x1229.jpg 1536w, https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean300_Aufbauskizze-510x408.jpg 510w\" sizes=\"auto, (max-width: 2000px) 100vw, 2000px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/a>\t\t\n<style>\n#image_1802420748 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-931346547 > .col-inner {\n  padding: 0px 30px 0px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1733624675 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section section-top-space\" id=\"section_1529467318\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row align-center\"  id=\"row-659643962\">\n\n\n\t<div id=\"col-1902548328\" class=\"col medium-9 small-12 large-9\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div class=\"e5_video_container\"><iframe loading=\"lazy\" class=\"e5_video\" data-lazy-src=\"https:\/\/www.youtube.com\/embed\/lA4ledfS1Iw?autoplay=0&mute=1&autohide=1&controls=1&showinfo=0&frameborder=0&rel=0&enablejsapi=1&loop=1\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><img decoding=\"async\" src=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/09\/AirClean_Inhaltsseite_grau-300x240.jpg\" class=\"e5_video_thumbnail\" \/><button class=\"e5_video_play\"><img decoding=\"async\" src=\"https:\/\/www.limodor.com\/wp-content\/mu-plugins\/limodor\/images\/playButton.svg\" \/><\/button><\/div>\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1529467318 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section section-bottom-space\" id=\"section_270114754\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-1659926329\">\n\n\n\t<div id=\"col-1064542220\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div class=\"e5-accordion-container\"><div class=\"e5-accordion-category-container\"><h3 class=\"e5-accordion accordion-header single-category\" data-categories=\"Zentrall\u00fcftungssystem\">FAQ on the subject of central ventilation system<\/h3><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorwhy-is-a-control-unit-and-sensors-useful-for-basement-ventilation\" data-categories=\"Basement,Central ventilation system,Fitness &amp; Wellness,New construction,Renovations\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Why is a control unit and sensors useful for basement ventilation?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>Effective dehumidification works only when the humidity outside is lower than inside. This is also temperature dependent. The controller uses the sensors to detect when optimal ventilation conditions are present. Only then it activates the ventilation. Faulty ventilation with warm humid air from outside is prevented.<\/p>\n<p>Often in basement rooms are located laundry room, laundry drying room, sauna or fitness room. Surges of moisture, for example after a sauna session or after hanging up a load of wet laundry, are detected by the moisture sensor and the ventilation is activated at intensive level for a limited time to remove the moist air from the room as quickly as possible.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchordoes-basement-ventilation-quickly-get-the-steam-out-of-the-room-after-a-sauna-session\" data-categories=\"Basement,Central ventilation system,Fitness &amp; Wellness,Living rooms,New construction,Renovations\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Does basement ventilation quickly get the steam out of the room after a sauna session?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>Yes, the control system detects a momentary high moisture load and automatically activates the ventilation, which quickly and efficiently brings the steam outside. At the same time, however, it ensures that in normal everyday life, ventilation only takes place when the outside air is drier than the basement air. this provides optimal cellar climate.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorare-there-basement-ventilation-variants-for-single-and-multi-family-houses\" data-categories=\"Basement,Central ventilation system,Fitness &amp; Wellness,New construction,Renovations\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Are there basement ventilation variants for single and multi-family houses?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>Yes, individual systems can be realized for both single-family houses and apartment buildings. They are planned individually according to the size and situation on site. In larger properties, where basements are shared by many residents, it is often useful to have more sensors, additional or more powerful ventilation elements, and other controls. Compact single-family basements are individually designed in terms of ventilation to suit the particular use by the homeowners. Where desired and appropriate, they can be integrated with the rest of the rooms in the house in a common ventilation concept or equipped as needed, for example, with a sauna ventilation.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchoris-basement-ventilation-standardized\" data-categories=\"Basement,Central ventilation system,New construction,Renovations\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Is basement ventilation standardized?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>LIMODOR basement ventilation systems are available in a standardized basic configuration as well as in a con\ufb01guration that can be planned as desired.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorcan-a-living-room-ventilation-manage-an-evening-with-many-guests\" data-categories=\"Central ventilation system,Kitchen,Living room,Living rooms,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Can a living room ventilation manage an evening with many guests?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>Yes. Some systems even have a &#8220;party mode&#8221;, which reacts to the temporarily increased load caused by many people in the room and adjusts the ventilation output accordingly. At the end of the party, the system falls back to the particularly energy-efficient everyday operation.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchordoes-a-living-room-vent-run-all-the-time-even-when-im-not-at-home\" data-categories=\"Central ventilation system,Living room,Living rooms,New construction,Renovations,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Does a living room vent run all the time, even when I'm not at home?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>This is system and control dependent. Often, central ventilation systems have a very economical base load operation when the occupants are absent, which only takes corrective action for a few minutes to ensure the set room climate parameters. However, these change little in empty rooms. Individual fans or decentralized systems can also be switched off completely as required.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorcan-i-still-open-windows-or-patio-doors\" data-categories=\"Central ventilation system,Living room,Living rooms,New construction,Renovations,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Can I still open windows or patio doors?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>Of course! For example, most controlled ventilation systems have a summer mode that takes into account the active use of a terrace or balcony and adjusts the ventilation function accordingly. In cold or bad weather, on the other hand, the best indoor climate is always ensured without energy-consuming window opening.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorhow-are-large-storage-rooms-e-g-lattice-cellars-in-apartment-blocks-ventilated\" data-categories=\"Basement,Central ventilation system,Garage,New construction,Renovations,Storage room,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">How are large storage rooms, e.g. lattice cellars in apartment blocks, ventilated?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>In this case, a powerful fan box is the ideal solution, which simultaneously extracts air at several points and brings it outside via poppet valves installed in a central exhaust pipe running across the basement. Dry fresh air enters the basement from outside via a second fan box, a central supply air pipe and poppet valves in the reverse direction. A control system ensures that the ventilation is only activated when ventilation conditions are optimal.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorare-fire-and-smoke-spread-possible-through-central-air-vents\" data-categories=\"Central ventilation system,New construction,Renovations,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Are fire and smoke spread possible through central air vents?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>To prevent fire and smoke from spreading through the exhaust ducts of a central ventilation system in the event of a fire, the building code prescribes standardized protective devices tested by independent testing bodies for their function and effect, and installation principles to be observed. These include, above all, cold smoke barriers and fire protection bulkheads or dampers. They are installed in the pipe network, are maintenance-free and automatically and safely close the pipe in case of fire. A suction effect caused by the prevailing temperature-related pressure differences is thus prevented.<\/p>\n<p>Fire protection bulkheads or dampers separate the room affected by a fire by heat-resistantly locking the exhaust pipe leading out of it above a certain temperature, thus preventing the fire from spreading to the rest of the pipe system. Cold smoke barriers prevent the penetration of smoke and vapors in ventilation units in the other rooms. They are closed by a spring as standard and are opened only when the fans are in operation by the airflow leaving the room. This always ensures protection from smoke from the pipe system in areas not affected by the fire.<\/p>\n<p>Single-pipe ventilation systems and fans must be installed professionally and in accordance with building codes to provide this life-saving safety. Fire protection bulkheads and cold smoke barriers are included in Limodor&#8217;s product range as accessories and meet the highest safety standards. In the Limodor single-pipe ventilation system, the fire protection devices are already integrated in the fan housing.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorhow-is-a-central-ventilation-system-controlled\" data-categories=\"Basement,Central ventilation system,Fitness &amp; Wellness,Living rooms,New construction,Renovations,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">How is a central ventilation system controlled?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>The control of a central ventilation system has different functions depending on the specific design. In the AirClean system, the central fresh air supply and several decentralized exhaust air units, such as the Limodor F\/M single-pipe fans, are controlled in an optimally coordinated manner for base load operation by a control element mounted in the electrical control box. Demand ventilation, party mode or summer mode are also set via the central control. Exhaust air elements are additionally individually controllable in each room. They can, for example, be switched from base load to full load for a short time in the bathroom by means of a humidity sensor or in the toilet by means of a motion sensor and thus quickly perform their respective ventilation task.<\/p>\n<p>A special case is the AirBase basement ventilation: Here, the controller receives measurement signals from humidity and temperature sensors located in the basement and outside. Depending on these signals, cellar drying is activated when conditions are optimal. But even here, for example with the Limodor F\/M-EC single-pipe ventilation system with humidity module, the humid air surge of a sauna can be quickly extracted at full capacity. Mold growth and basement moisture are optimally prevented by this combination of energy-saving base load operation and short-term demand ventilation at full load.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorwhy-do-i-need-basement-ventilation\" data-categories=\"Basement,Central ventilation system,Fitness &amp; Wellness,Living rooms,New construction,Renovations,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Why do I need basement ventilation?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>In times of scarce and expensive living space, the basement is increasingly coming into focus as an additional reserve of space. For example, for the home office, but also for a sauna or a fitness room. A well-known problem even in modern houses: Especially in summer, mold or musty smells often form on the cool basement walls due to condensation of moist warm outside air. Simple ventilation is of no use here, it often even aggravates the situation.<\/p>\n<p>The AirBase basement ventilation system therefore works sensor-controlled. Humidity and temperature inside and outside are measured. A smart control unit ensures that only dry outside air enters the house. Humid or odorous indoor air is extracted. This provides optimal cellar drying. Sauna ventilation can also be integrated. Mold protection is thus guaranteed, as is full flexibility in design and operation analogous to residential ventilation.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorcentralized-decentralized-or-single-room-solution\" data-categories=\"Basement,Bathroom,Central ventilation system,Decentralized living space ventilation,Garage,Living room,Living rooms,Renovations,Storage room,toilet,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">Centralized, decentralized or single room solution?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>Sometimes central ventilation is optimal. For example, if it can be planned from scratch for the entire living area in a new building with maximum efficiency. Or as basement ventilation, where a smart control system ensures condensation, mold growth and typical musty basement odors for the entire basement floor under sensor control.<\/p>\n<p>A decentralized living space ventilation system with heat recovery is often ideal for renovations. It is ideal for retrofitting small apartments, offices or bedrooms, for example, where installation costs are manageable. In addition, these systems are very quiet and extremely energy efficient.<\/p>\n<p>Sometimes, however, single units in only some rooms such as toilets, bathrooms, wellness rooms, utility rooms or garages are the best solution. Control modules allow the fans to be optimally adapted to the task at hand and automated. Combined with properly executed window ventilation in the rest of the apartment, this creates an inexpensive, yet energy-saving and comfortable solution.<\/p>\n<p>The advantages and disadvantages, and then the appropriate system selection, are best made together with the architect or builder and the installer who will plan and implement the ventilation design.<\/p>\n<\/div><\/div><div class=\"e5-accordion e5-accordion-article\" id=\"e5Anchorhow-flexible-are-central-ventilation-systems\" data-categories=\"Central ventilation system,Ventilation systems\"><a href=\"#\" class=\"details-link accent\"><div class=\"e5-accordion-title-container\"><span class=\"e5-accordion-title\">How flexible are central ventilation systems?<\/span><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"17\" class=\"polygon\" viewBox=\"0 0 20 17\"><path id=\"Polygon_6\" data-name=\"Polygon 6\" d=\"M9.138,1.465a1,1,0,0,1,1.724,0l8.252,14.028A1,1,0,0,1,18.252,17H1.748a1,1,0,0,1-.862-1.507Z\" transform=\"translate(20 17) rotate(180)\" fill=\"#0069b4\"\/><\/svg><\/div><\/a><div class=\"row dropdown-content\"><p>The advantage of centrally controlled living space ventilation is an optimal feel-good climate throughout the entire living area. The connected supply air and exhaust air units run at a permanent, very energy-saving base load level. However, each of these ventilation units can be individually switched to other operating levels by means of overrun relays, humidity control, motion detectors or similar. In the case of WC ventilators or bathroom ventilation systems, for example, the respective ventilation elements are adapted to the optimum operating mode in terms of space and time. The great advantage of this is that the supply and exhaust air are not simply routed through the house wall, but first through the heat exchanger. This means that the thermal energy of the exhaust air, which would otherwise be lost, tempers the incoming fresh air. Each time a small, but in total a large contribution to climate protection and heating cost reduction.<\/p>\n<p>The AirClean system also offers winter and summer modes, as well as &#8220;party mode&#8221;. With many visitors at the same time, this ensures that the temperature, humidity and fresh air supply remain comfortable for everyone by increasing the ventilation capacity. Maximum flexibility is therefore always ensured with controlled residential ventilation from Limodor.<\/p>\n<\/div><\/div><\/div><\/div>\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_270114754 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section\" id=\"section_1762894625\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-1997863264\">\n\n\n\t<div id=\"col-1148721990\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div \r\n                id=\"e5-oxomi-2629372616\" \r\n                class=\"e5-oxomi-output\" \r\n                data-portal-id=\"2025060\"\r\n                data-oxomi_type_select=\"selectOptionCategories\"\r\n                data-oxomi_keyword=\"\"\r\n                data-oxomi_keyword_filter_select=\"\"\r\n                data-oxomi_categories=\"AirClean\"\r\n                data-oxomi_types=\"\"\r\n                data-oxomi_brands=\"\"\r\n                data-oxomi_tags=\"\"\r\n                data-oxomi_document_id=\"\"\r\n                data-oxomi_document_page=\"\"\r\n                data-oxomi_search=\"\"\r\n                data-oxomi_group_by_select=\"\"\r\n                data-oxomi_group_by_filter=\"\"\r\n                data-lang=\"en\"\r\n            >\r\n            <\/div>\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1762894625 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n<\/style>\n\t<\/section>\n\t\n\n\t<section class=\"section section-bottom-space\" id=\"section_946133948\">\n\t\t<div class=\"section-bg fill\" >\n\t\t\t\t\t\t\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row row-collapse align-middle align-right ventilation-system-overview\"  id=\"row-274244780\">\n\n\n\t<div id=\"col-1175944845\" class=\"col medium-6 small-12 large-3\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-3691441256\" class=\"text\">\n\t\t\n\n<p class=\"sub-headline\">Not found the right thing?<\/p>\n\t\t\n<style>\n#text-3691441256 {\n  text-align: center;\n}\n@media (min-width:550px) {\n  #text-3691441256 {\n    text-align: right;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1763154313\" class=\"col medium-6 small-12 large-3\"  >\n\t\t\t\t<div class=\"col-inner text-center\"  >\n\t\t\t\n\t\t\t\n\n<a href=\"\/en\/vents\/ventilation-systems\/\" class=\"button primary is-outline is-small\"  style=\"border-radius:10px;\">\n\t\t<span>back to the overview<\/span>\n\t<\/a>\n\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1763154313 > .col-inner {\n  padding: 0px 0px 0px 0px;\n  margin: 20px 0px 0px 0px;\n}\n@media (min-width:550px) {\n  #col-1763154313 > .col-inner {\n    padding: 0px 0px 0px 30px;\n    margin: 0px 0px 0px 0px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_946133948 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n}\n<\/style>\n\t<\/section>\n\t","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":3313,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-7199","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Airclean | Central ventilation system<\/title>\n<meta name=\"description\" content=\"Controlled control of supply and exhaust air for all rooms with efficient heat recovery.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Airclean | Central ventilation system\" \/>\n<meta property=\"og:description\" content=\"Controlled control of supply and exhaust air for all rooms with efficient heat recovery.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/\" \/>\n<meta property=\"og:site_name\" content=\"Limodor AT\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-31T18:46:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/10\/LIMODOR_Home.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/\",\"url\":\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/\",\"name\":\"Airclean | Central ventilation system\",\"isPartOf\":{\"@id\":\"https:\/\/www.limodor.com\/en\/#website\"},\"datePublished\":\"2023-08-24T08:35:44+00:00\",\"dateModified\":\"2023-10-31T18:46:18+00:00\",\"description\":\"Controlled control of supply and exhaust air for all rooms with efficient heat recovery.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.limodor.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solutions\",\"item\":\"https:\/\/www.limodor.com\/en\/vents\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Ventilation systems\",\"item\":\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Central ventilation system\",\"item\":\"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"AirClean\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.limodor.com\/en\/#website\",\"url\":\"https:\/\/www.limodor.com\/en\/\",\"name\":\"LIMODOR\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.limodor.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.limodor.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.limodor.com\/en\/#organization\",\"name\":\"LIMODOR L\u00fcftungstechnik GmbH & Co KG\",\"url\":\"https:\/\/www.limodor.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.limodor.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/10\/LIMODOR_Logo_square.svg\",\"contentUrl\":\"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/10\/LIMODOR_Logo_square.svg\",\"width\":1,\"height\":1,\"caption\":\"LIMODOR L\u00fcftungstechnik GmbH & Co KG\"},\"image\":{\"@id\":\"https:\/\/www.limodor.com\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Airclean | Central ventilation system","description":"Controlled control of supply and exhaust air for all rooms with efficient heat recovery.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/","og_locale":"en_US","og_type":"article","og_title":"Airclean | Central ventilation system","og_description":"Controlled control of supply and exhaust air for all rooms with efficient heat recovery.","og_url":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/","og_site_name":"Limodor AT","article_modified_time":"2023-10-31T18:46:18+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/10\/LIMODOR_Home.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/","url":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/","name":"Airclean | Central ventilation system","isPartOf":{"@id":"https:\/\/www.limodor.com\/en\/#website"},"datePublished":"2023-08-24T08:35:44+00:00","dateModified":"2023-10-31T18:46:18+00:00","description":"Controlled control of supply and exhaust air for all rooms with efficient heat recovery.","breadcrumb":{"@id":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/airclean\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.limodor.com\/en\/"},{"@type":"ListItem","position":2,"name":"Solutions","item":"https:\/\/www.limodor.com\/en\/vents\/"},{"@type":"ListItem","position":3,"name":"Ventilation systems","item":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/"},{"@type":"ListItem","position":4,"name":"Central ventilation system","item":"https:\/\/www.limodor.com\/en\/vents\/ventilation-systems\/central-ventilation-system\/"},{"@type":"ListItem","position":5,"name":"AirClean"}]},{"@type":"WebSite","@id":"https:\/\/www.limodor.com\/en\/#website","url":"https:\/\/www.limodor.com\/en\/","name":"LIMODOR","description":"","publisher":{"@id":"https:\/\/www.limodor.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.limodor.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.limodor.com\/en\/#organization","name":"LIMODOR L\u00fcftungstechnik GmbH & Co KG","url":"https:\/\/www.limodor.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.limodor.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/10\/LIMODOR_Logo_square.svg","contentUrl":"https:\/\/www.limodor.com\/wp-content\/uploads\/2023\/10\/LIMODOR_Logo_square.svg","width":1,"height":1,"caption":"LIMODOR L\u00fcftungstechnik GmbH & Co KG"},"image":{"@id":"https:\/\/www.limodor.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/pages\/7199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/comments?post=7199"}],"version-history":[{"count":3,"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/pages\/7199\/revisions"}],"predecessor-version":[{"id":41758,"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/pages\/7199\/revisions\/41758"}],"up":[{"embeddable":true,"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/pages\/3313"}],"wp:attachment":[{"href":"https:\/\/www.limodor.com\/en\/wp-json\/wp\/v2\/media?parent=7199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}