FAQ
Everything about the exhaust air system
Depending on whether it is an axial fan, a radial fan, or a single-pipe fan, the installation options vary. Axial fans such as LIMAX, PRIMO, or ENTER are typically installed in short, straight ducts—for example, in bathroom or toilet ventilation systems that run directly through an exterior wall.
Centrifugal fans are also installed directly into the ductwork and are suitable for longer ducts. Depending on the structural situation, however, fire protection elements must be installed separately.
The LIMODOR single-pipe ventilation system offers the greatest flexibility. The fans can be installed as flush-mounted or surface-mounted units, in or on walls, or on the ceiling. They cover all applications throughout the home and can also function as a central exhaust system in the attic, as individual fans, in groups, or in combination with other ventilation elements.
It depends on the model. Very old LIMODOR fan models (e.g., C/E, F/D) have been operating with their original fan element for half a century. Should it ever become defective, it can be replaced with a replacement fan, depending on the model and availability. Our sales team can provide specific information and assistance regarding this.
Replacement fans are available for the LIMODOR ONE, F/M, B, and W models; LIMODOR ONE fans also fit into LIMODOR F/M housings. When replacing fans, LIMODOR F/M EC fans are always replaced with LIMODOR ONE fans.
The fan should be positioned as close as possible to the source of moist or odorous air. This improves the capture of contaminated air and increases efficiency.
Do not install fans in areas where the airflow is obstructed by walls, furniture, or other obstacles.
Inflowing air—such as through doors or supply air vents—should be able to flow as unimpeded as possible toward the exhaust unit.
In modern, airtight buildings, ensure there is sufficient supply air. If necessary, supply air vents should be installed to prevent excessive negative pressure and operational malfunctions.
The layout of the ventilation system should not cause unpleasant drafts.
If there are fireplaces or room-air-dependent gas appliances in the building, the applicable building and safety regulations must be followed, and sufficient combustion air must be ensured. Otherwise, there is a risk that exhaust gases—including carbon monoxide—will enter the room.
The exhaust air should be routed to the outside via the shortest and straightest path possible. Every additional bend, every constriction, and every unnecessary length of duct increases flow resistance and can reduce airflow capacity.
Filters should be inspected regularly and at shorter intervals, and replaced as necessary.
Therefore, fans with motion sensors (e.g., LIMODOR ONE) are best suited to ensure regular activation. At the same time, an adequate supply of fresh air should be ensured (e.g., via AIRONOVA).
The LIMODOR ONE (and its predecessor, the F/M-EC) features a plug-in circuit board and sensor system that allows for quick conversion to a different activation mode or a combination of modes by simply swapping out these control modules.
LIMODOR ONE fan inserts are available or can be retrofitted with sensor modules or controllers for motion, humidity, CO2, VOCs (hazardous gases), external control, timers, bus inputs, or combinations of these control options.
In addition, almost all LIMODOR fans can be controlled via door contacts or light switches, timers, delay switches, or interval relays.
Everything about the decentralized ventilation system
Decentralized residential ventilation systems are particularly well-suited for renovations, retrofits, and individual residential or commercial spaces where installing a central ventilation system is not cost-effective or structurally feasible. They also offer an efficient and flexible solution for partial modernizations or phased renovations.
Compared to centralized ventilation systems, the installation effort is significantly lower. Depending on the system, all that is required is a core drill hole and an electrical connection. This makes it possible to carry out projects with manageable installation costs—both in residential buildings and in small office or commercial spaces.
Decentralized systems are the right choice when individual rooms or units need to be ventilated independently, or when retrofitting an air duct network is not possible or cost-effective. They enable demand-based ventilation with heat recovery without requiring extensive alterations to the building structure.
Decentralized residential ventilation systems with heat recovery use the heat from the exhaust air to preheat the incoming outdoor air. This reduces heat loss through ventilation and improves the building’s energy efficiency. At the same time, a continuous supply of fresh air is ensured.
To ensure efficient operation, factors such as room size, the required air change rate, room usage, unit placement, and airflow to the outside must be taken into account. Similarly, requirements for sound insulation, energy efficiency, and filter technology should be considered during the planning phase.
Depending on the application, different filters can be used—for example, particle filters, fine dust filters, or activated carbon filters. They improve air quality, protect the device from contamination, and allow it to be used even in areas with stricter hygiene or outdoor air quality requirements.
Modern decentralized residential ventilation systems use energy-efficient EC fans and require very little electrical power. Heat recovery further reduces heat loss, making these systems both energy-efficient and cost-effective.
Maintenance is essentially limited to regularly inspecting and replacing the filters in accordance with the manufacturer’s specifications. This ensures that air quality, energy efficiency, and the system’s long-term performance are maintained.
Everything about the supply air system
Supply air systems are suitable for any location where a controlled supply of fresh air needs to be ensured—for example, as a supplement to exhaust air systems or in buildings with high airtightness. They support continuous air exchange and help maintain a balanced indoor climate.
Supply air vents should be positioned so as to ensure an unobstructed supply of fresh air. Furniture, curtains, or other furnishings must not obstruct the airflow. It is often recommended to install them near a radiator or in the window reveal to further improve thermal comfort.
Key factors include the required air flow rates, the placement of supply air vents, the airflow patterns within the building, and requirements for sound, thermal, and moisture protection. Similarly, the building’s structural characteristics and future maintenance should be taken into account as early as the planning phase.
In modern, airtight buildings, a combination of supply and exhaust air is often recommended. While the exhaust air system reliably removes stale air, the supply air system ensures the necessary inflow of fresh air. This prevents negative pressure and ensures efficient air exchange.
Passive supply air systems operate without their own fan and therefore do not require electricity. They provide a controlled supply of fresh air, reduce heat loss through ventilation compared to windows that are kept open all the time, and can effectively keep out noise, pollen, fine dust, and insects.
Depending on the application, particle filters, fine dust filters, or activated carbon filters can be used. They improve air quality, protect indoor spaces from pollen and pollutants, and help ensure the system’s long service life. Regular filter replacement ensures consistently high performance.
Depending on the model, a supply air system consists of an outdoor air grille, an air duct, soundproofing and filter elements, and an interior grille with adjustable airflow. Wind pressure relief valves or special installation solutions for the window reveal can be integrated as options.
In buildings with room-air-dependent fireplaces or gas appliances, an adequate supply of fresh air must be ensured. Properly designed supply air systems support the necessary air flow and help ensure compliance with applicable safety requirements.
Everything about the centralized ventilation system
Building geometry, air flow rates, ductwork, sound insulation, fire protection, and the positioning of supply and exhaust air outlets should be taken into account as early as the planning phase. Careful design lays the foundation for energy-efficient and consistently reliable operation.
Central ventilation systems are particularly well-suited for new construction projects and extensive renovations where controlled ventilation of the entire building is planned. They offer a high level of living comfort, an energy-efficient supply of fresh air, and enable centralized control of all ventilation zones.
A central ventilation system supplies multiple rooms via a shared ductwork system and ensures continuous air exchange throughout the building. This optimizes air quality, energy efficiency, and user comfort. At the same time, heat recovery reduces heating energy consumption.
Modern central ventilation systems feature demand-based controls that automatically adjust airflow rates to match current usage. Depending on the system, humidity, CO₂, or temperature sensors can be integrated. This ensures demand-based ventilation while maintaining high energy efficiency.
Building geometry, air flow rates, ductwork, sound insulation, fire protection, and the positioning of supply and exhaust air outlets should be taken into account as early as the planning phase. Careful design lays the foundation for energy-efficient and consistently reliable operation.
Sensors enable the ventilation output to be automatically adjusted to actual room conditions. In basement ventilation systems in particular, humidity and temperature sensors prevent improper ventilation and support controlled dehumidification by activating the ventilation only under suitable climatic conditions.
Heat recovery transfers the heat contained in the exhaust air to the incoming outdoor air. This reduces heat loss through ventilation, increases the building’s energy efficiency, and ensures a continuous supply of fresh air.
In addition to efficient heat recovery, demand-based control, flow-optimized air ducts, properly sized airflow rates, and energy-efficient fans contribute significantly to the system’s overall energy efficiency.
To ensure long-term efficient operation, filters should be inspected regularly and replaced according to the manufacturer’s specifications. In addition, it is recommended to regularly inspect the ventilation control unit, as well as the air ducts and components, to ensure hygiene, air quality, and system performance over the long term.
Tips for all living spaces
Warm, humid outside air can condense on the cool basement walls, leading to moisture, mold, or a musty odor. A sensor-controlled basement ventilation system compares indoor and outdoor conditions and ventilates only when drier outside air is available.
After a sauna session or an intense workout, moisture and stale air should be removed from the room as quickly as possible without unnecessarily cooling the space. To achieve this, high-performance exhaust fans can operate at high capacity for short periods and then shut off or switch to an energy-saving base-load mode. Automatic humidity control is particularly convenient.
Passive supply air systems such as AirOnova provide a continuous supply of fresh air through the exterior wall or window reveal. Filters trap dust and pollen, among other things, while soundproofing elements can reduce outside noise.
In bathrooms and combined bathroom-toilet rooms, single-pipe ventilation systems or fans are used, depending on the situation. Key factors include room size, desired dehumidification capacity, frequency of use, length of the exhaust duct, and the available supply air.
Decentralized residential ventilation systems with heat recovery are particularly well-suited for individual living rooms, bedrooms, or offices. Depending on the system, the main requirements are a connection through the exterior wall and a power connection; there is no need to install a central duct network within the building.
For a small office, depending on the requirements, an exhaust fan mounted on the wall or an axial fan installed through a short wall opening can be used. If heat recovery is also desired, decentralized residential ventilation systems are an option.
Decentralized residential ventilation systems are suitable for retrofitting individual office spaces because they do not require a central duct network. Depending on the unit, the main requirements are essentially a core hole drilled through the exterior wall and an electrical connection.
A passive supply-air unit such as AirOnova can supply outdoor air without its own fan. Sound insulation, filters that trap dust, pollen, and allergens, and a wind pressure safety device ensure comfort.
It is particularly important to ensure an adequate supply of fresh air and protection against carbon monoxide as well as explosive, toxic, or flammable substances. The website recommends a combination of exhaust and supply air, or a properly balanced ventilation system, to achieve this.
Yes. Passive supply air elements do not require their own fan and draw in outside air through a wall vent or a system installed in the window reveal. Filters, insect screens, sound insulation, and an optional wind pressure relief valve can be integrated into the system.
Yes. Single-duct ventilation systems with humidity sensors can activate automatically once a certain humidity level is reached and remove the humid air. This ensures that the garage is ventilated as needed and reduces humidity levels.
Yes, if a direct connection through the exterior wall is possible, compact, decentralized residential ventilation systems with heat recovery can be retrofitted with relatively little effort. This is suitable, for example, for living rooms, bedrooms, or offices, and in some cases also for basements located in appropriate areas.
For effective dehumidification, both indoor and outdoor temperature and humidity must be taken into account. The control system detects when conditions are suitable for ventilation, thereby preventing warm, humid outdoor air from further increasing the load on the basement.
Several quality factors count: A currently accumulating large amount of moisture must be transported out of the room into the open air as quickly as possible and at the same time without a large loss of energy. In addition, the room should not cool down much in the cold season to prevent condensation. This requires high-performance exhaust air units that run in an automated manner for short periods of time in full-load operation and then either turn off or run in an energy-efficient base-load mode. Ventilation activation is done by manual on/off or better automatically via pure efficient humidity control.
Yes, the control system detects a momentary high moisture load and automatically activates the ventilation, which quickly and efficiently brings the steam outside. At the same time, however, it ensures that in normal everyday life, ventilation only takes place when the outside air is drier than the basement air. this provides optimal cellar climate.
Yes. Basement ventilation systems can be designed for both single-family homes and larger buildings. The number and capacity of the ventilation units, as well as the sensor system, are tailored to the size and use of the rooms.
LIMODOR offers basement ventilation systems in both a standardized basic configuration and customizable designs. The best solution depends on the building, the size of the room, and how it is used.
Effective dehumidification works only when the humidity outside is lower than inside. The controller uses combined temperature and humidity sensors to detect when optimal ventilation conditions exist. Only then it activates the ventilation. Faulty ventilation is prevented. Another important criterion is the wellness or fitness areas increasingly located in basements. Moisture is typically generated in these, often large amounts in a short period of time as in sauna airing. This must be reliably detected and extracted, ideally without making these rooms uncomfortably cool. At the same time, unpleasant smell of sweat is also removed with and the rest of the storage rooms are protected from mold and cellar stink. The smart control system takes care of that.
No. Depending on the model, the fan can be turned on with the light switch and then left to run for a while, or it can be automatically turned on and off in response to motion or humidity.
A toilet fan uses very little energy because it runs only for a short time and, depending on the control system, shuts off automatically. This ensures that ventilation occurs only when it is actually needed.
In a pure exhaust ventilation system, stale air is extracted from the room. The missing air volume is replaced by air flowing in from the adjacent living area, so that—unlike with direct window ventilation—cold outside air does not flow into the room.
That depends on the unit’s performance. According to LIMODOR, a typical toilet fan in a standard restroom takes about five to seven minutes to remove odors.
Modern ventilation systems operate on an as-needed basis and, especially during the cold season, prevent unnecessary heat loss caused by leaving windows open for long periods. Decentralized systems with heat recovery also utilize the heat from exhaust air, while sensors and controls adjust operating times to actual demand.
The ventilation units are equipped with filters or insect screens designed to prevent insects from entering. At the same time, this eliminates the need to keep windows open all the time, through which insects might otherwise enter the room.
Depending on the control system, air exchange can be specifically scheduled for cooler nighttime hours. An intensive ventilation function can also help replace warm indoor air with cooler nighttime air before bedtime.
Sound insulation in covers or wall openings reduces both the noise from the ventilation unit and outside noise. Decentralized residential ventilation systems are therefore specifically designed for bedrooms, where a low noise level is important.
That depends on the ventilation system as well as how airtight the rooms and doors are. A controlled airflow can be particularly beneficial in well-insulated, airtight buildings. In the case of fireplaces, a sufficient supply of fresh air must be ensured in all cases.
Yes. Some systems have a “party mode” that increases ventilation capacity when there are temporarily more people in the room. Afterward, the system can return to its energy-saving normal operation.
That depends on the system and the control mechanism. Centralized ventilation systems can operate in an energy-efficient base-load mode, while individual or decentralized units can be turned off depending on their design and demand.
Yes. A ventilation system does not prevent windows or doors from being opened. In controlled systems, a “summer mode” can adjust operation to accommodate situations such as an open patio or balcony.
In this case, a powerful fan box is the ideal solution, which simultaneously extracts air at several points and brings it outside via poppet valves installed in a central exhaust pipe running across the basement. Dry fresh air enters the basement from outside via a second fan box, a central supply air pipe and poppet valves in the reverse direction. A control system ensures that the ventilation is only activated when ventilation conditions are optimal.
Single-duct ventilation systems with humidity sensors can activate automatically when humidity levels rise and remove the moist air. If the room is located in the basement, it can also be integrated into a centrally controlled basement ventilation system.
The supply air vent should be positioned so that air can flow freely into the room and is not blocked by furniture, curtains, or similar objects. Since passive supply air vents do not actively heat the outside air, the website recommends placing them near or above a radiator.
AirOnova supply air systems run either as a straight pipe through the house wall or, when installed in the window reveal, as a pipe with a supplementary 90° deflection and a so-called wide duct that is walled into the window reveal.
Starting from the outside, fresh air enters through a ventilation grille. On its way through the tube, it passes an insect screen and an optional wind pressure safety device. Noise protection is made possible by a silencer in the pipe. The fresh air exits through a so-called filter trough on the inner wall. The filter tray contains a filter insert that binds allergens and dust. The outgoing air volume can be infinitely adjusted manually. Drafts are prevented by this system.
LIMODOR’s decentralized residential ventilation systems are equipped with filters on both the supply and exhaust air sides. Depending on the filter type, dust, pollen, and other particles can be trapped from the outside air. To ensure maximum effectiveness, the filters must be checked regularly and replaced as needed.
That depends on the system. In reversible units, the flow direction alternates between supply and exhaust air, while systems with two fans can handle both supply and exhaust air simultaneously. In both cases, heat from the exhaust air is used to preheat the incoming fresh air.
The heat exchanger uses a large portion of the heat contained in the exhaust air to temper the incoming fresh air. As a result, less heating energy is lost during air exchange than when windows are left open for longer periods.
That depends on the model. With the AirClean system, the central fresh air supply and several decentralized exhaust air elements are coordinated via a control panel in the electrical distribution box. This allows you to set the system to base load mode, as well as demand mode, party mode, and summer mode. Individual exhaust air elements can also be temporarily switched to a higher output in the respective room, for example via humidity or motion sensors.
In times of scarce and expensive living space, the basement is increasingly coming into focus as an additional reserve of space. For example, for the home office, but also for a sauna or a fitness room. A well-known problem even in modern houses: Especially in summer, mold or musty smells often form on the cool basement walls due to condensation of moist warm outside air. Simple ventilation is of no use here, it often even aggravates the situation.
The AirBase basement ventilation system therefore works sensor-controlled. Humidity and temperature inside and outside are measured. A smart control unit ensures that only dry outside air enters the house. Humid or odorous indoor air is extracted. This provides optimal cellar drying. Sauna ventilation can also be integrated. Mold protection is thus guaranteed, as is full flexibility in design and operation analogous to residential ventilation.
Exhaust ventilation systems typically operate at higher capacity only when they are actually needed, such as when there is moisture in the bathroom or odors in the restroom. Depending on the system, activation is triggered by a light switch, a timer, motion, or humidity, which helps prevent unnecessary continuous operation.
In many LIMODOR exhaust air systems, fan units can be replaced without having to remove the built-in housing from the wall. Depending on the fan type, different control systems can also be retrofitted or replaced.
Depending on whether axial fan, centrifugal fan or single-pipe fan, the mounting options are variable. Axial flow fans such as the Limax are typically installed in straight short ducts, such as a bathroom or toilet vent, that pass directly through the exterior wall. Centrifugal fans are also installed directly in the pipe run and are also suitable for longer pipes. However, depending on the structural situation, fire protection elements must be installed separately.
The most flexible is the Limodor single-pipe ventilation system. The fans can be installed as flush-mounted and surface-mounted variants, in and on walls or on the ceiling. They cover all areas of application in the house and also work as central exhaust in the attic, as individual fans, groups or in combination with other ventilation elements.
Ventilation systems are indispensable partners in modern new buildings as well as in renovation projects. Energy efficiency, noise protection, comfort, safety from allergens, fine dust, pathogens or insects – there is a lot to be said for modern ventilation. It is important to always proceed with common sense and to obtain detailed advice.
Sometimes central ventilation or a decentralized residential ventilation system with heat recovery is ideal. The latter is ideal for retrofitting offices or bedrooms, for example, where installation costs are manageable. Sometimes, however, single units in only some rooms such as toilets and bathrooms combined with properly performed window ventilation are an inexpensive, yet energy-saving and comfortable solution. All of these issues are best discussed with the architect or builder and the installer who will design and implement the ventilation layout.
For efficient air exchange, some factors should be considered:
- The position of the fan, e.g. in the bathroom or toilet, should be chosen as close as possible to the point of origin of the humid or odorous air. This increases efficiency and speed.
- Do not mount fans in blind spots or areas where the intake airflow will encounter obstructions.
- Air flowing in, e.g. through doors or supply air elements, should also be able to sweep in the direction of the extraction unit as undisturbed as possible in order to be able to absorb a maximum of moisture, especially in the bathroom.
- In times of increasingly tight rooms and doors, it is essential to ensure sufficient supply air for fireplaces, if necessary by means of separate supply air elements, in order not to produce toxic carbon monoxide.
- Exhausted air should be able to get outside in the shortest and straightest way possible. Any kink or constriction lowers the efficiency.
- Of course, the fan arrangement must not cause any unpleasant drafts.
A central ventilation system can be a good choice if the entire building is incorporated into a ventilation plan from the start. Decentralized residential ventilation systems are particularly well-suited for individual rooms and for retrofits, while individual ventilators can be used specifically in rooms such as bathrooms, restrooms, fitness and wellness rooms, storage rooms, or garages.
Ventilation systems are indispensable partners in modern new buildings as well as in renovation projects, and in times of energy and climate change they are valuable sustainability tools for the environment and the wallet. In order to generate maximum benefit with an economically sensible investment in new construction or renovation, some basic considerations should be made and expert advice sought from ventilation engineers, installers or planners:
- New construction or renovation? In the case of new buildings, optimal ventilation planning and thus full freedom of choice is possible. In the case of refurbishment, the aim should be to minimize the necessary construction work – such as the need to break through walls, the installation work required for pipes and electrical connections, and so on. – for retrofitting. Maximum energy efficiency must of course be ensured. Decentralized ventilation solutions or Exhaust air systems in individual rooms.
- Window opening versus investment for ventilation units: Fans are particularly useful wherever multiple synergies can be utilized. For example, energy efficiency with simultaneous protection against odor, noise, insects or pollutants. Toilets and bathrooms are difficult to ventilate quickly and efficiently by simply opening windows to remove odor or moisture. In the process, they also cool down in the cold season, which wastes energy and makes the indoor climate uncomfortable. An exhaust air system pays for itself particularly quickly.
- Capital expenditure: Centrally controlled complete system for the whole house? Heat recovery? Include basement? Or only ventilation of exposed rooms such as toilet, bathroom or sauna room? With which and how many fans can optimal effect be achieved?
- Maintenance effort: In the case of decentralized, exhaust air and supply air systems, the installed filters must be replaced regularly and, for example, insect screens must also be checked. For some central air systems, additional considerations include sometimes long, hard-to-reach ductwork or regular inspection of the heat pump where present. This increases maintenance costs.
- Operating costs: LIMODOR systems are extremely energy-efficient. However, some systems still run at a very economical base load level all day to ensure a constant indoor climate. Other systems such as single-pipe ventilators can be controlled in a particularly efficient and automated manner via humidity, time or movement modules, so that the additional costs for these components quickly pay for themselves. Economy optimal for renovations are also decentralized solutions with integrated heat exchanger.
The most important bonus of the Limodor venting system is the possibility of connecting many units to a single exhaust duct, which is routed through a roof outlet, for example. Elaborate piping and unsightly fan grilles on the facade are eliminated. Fire dampers are already integrated in the housing. Typically, this variant is used in multi-apartment buildings for toilet and bathroom ventilation.
The devices are very simple and can also be mounted according to the construction progress. In the shell is first walled only the separate housing with a protective cover, the connections for power and air are connected. With a few simple steps and minimal tools, the blower insert is later connected to the power supply and simply clicked into place.
As exhaust fans, Limodor single-pipe fans are true powerhouses that can be mounted in any position and will not be disturbed by longer piping or kinks. They are multifunctional and can be used as toilet vents, bathroom or kitchen ventilators as efficiently as components of central ventilation systems or basement ventilation systems.
Yes. According to the website, the LIMODOR B requires an installation depth of only eight centimeters, making it suitable even for thin partition walls.
A bathroom exhaust fan should be installed as close as possible to the source of high humidity, such as the shower or bathtub. At the same time, air from the area where it enters the room—for example, through the bathroom door—should be able to flow toward the fan as unobstructed as possible.
That depends, among other things, on the building, its use, the specific room, and the desired ventilation requirements. Another key factor is whether it’s a new construction or a renovation, and whether you’re looking for a solution for the entire home or just for individual rooms. Our information on ventilation systems and ventilation solutions by room type provides an initial overview.